Buyers Guide
Features
Advanced Double-Conversion Online UPS System
SMART UPS Pro for Critical Infrastructure
| Technology | |
| UPS Type | On-line |
| Execution | |
| Form Factor | Tower |
| Number of phases | |
| Specification | 1 phase input to ground with ground and 1-phase output from the ground |
| Input parameters | |
| Power | 1000VA / 800W |
| Input voltage | 220/230/240V |
| Input voltage range | 115 - 300 V |
| Current frequency | 40 -70 Hz (auto sensing) |
| Phases | one phase grounding |
| Output parameters | |
| Output voltage | 220/230/240 V ± 1% |
| Form voltage | pure sine wave |
| Current frequency | 50/60 Hz ± 1% |
| Automatic voltage regulation (AVR) | Yes |
| Switching time | 0 ms |
| Power factor correction | 0,8 |
| Harmonic voltage fluctuations | <3% (linear load) and <5% (with a non-linear load) |
| Crest factor | 03:01 |
| Protection and UPS equipment | |
| Surge Protection | Yes |
| Overload protection | Yes |
| UPS Login | Circuit breaker |
| Short circuit | Immediate load shedding or tripping of upstream circuit breaker |
| Protect the phone, fax, modem, LAN | 1 * RJ-11/45 |
| Ports and interfaces | |
| Dry contacts | No |
| USB-port | No |
| RS-232 | Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
| Port emergency shutdown EPO | No |
| SNMP | Built-in expansion slot for SNMP adapter |
| Connections of the generator input | No |
| Parallel UPS connection | No |
| Battery | |
| A type | Lead-acid, sealed, maintenance-free |
| Voltage and battery capacity | 12V / 7AH x 3 |
| Typical recharge time | 8 hours (up to 90% of full battery capacity) |
| Charging Current (Max) | 2A |
| Estimated battery backup time (at 50% load) | ~4,0 min. |
| Estimated battery backup time (at 100% load) | ~13,00 min. |
| Hot-swappable batteries | No |
| Connecting additional battery cabinets | No |
| Cold start | Yes |
| Battery protection | Automatic diagnostics, protection against overcharge and short-circuit |
| Physical parameters | |
| Output connectors | 2 x Euro sockets with redundant power and filtration |
| Dimensions (W * D * B) mm | 350*144*229 mm |
| Weight, kg | 11,5 kg |
| Indication | LCD-display (input and output voltage, current, frequency, battery charge level, load level |
| Sound alarm | Beep in battery mode, when the battery is low, overload and fault charger |
| Case features | |
| Material | Metal (0.5 mm) |
| Environmental Parameters | |
| Acoustic noise | <40 dB (at 1 meter from surface) |
| Working conditions | Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
| Guarantee | |
| Standard warranty | 1 year |
Specifications
Specifications
| Technology | |
| UPS Type | On-line |
| Execution | |
| Form Factor | Tower |
| Number of phases | |
| Specification | 1 phase input to ground with ground and 1-phase output from the ground |
| Input parameters | |
| Power | 1000VA / 800W |
| Input voltage | 220/230/240V |
| Input voltage range | 115 - 300 V |
| Current frequency | 40 -70 Hz (auto sensing) |
| Phases | one phase grounding |
| Output parameters | |
| Output voltage | 220/230/240 V ± 1% |
| Form voltage | pure sine wave |
| Current frequency | 50/60 Hz ± 1% |
| Automatic voltage regulation (AVR) | Yes |
| Switching time | 0 ms |
| Power factor correction | 0,8 |
| Harmonic voltage fluctuations | <3% (linear load) and <5% (with a non-linear load) |
| Crest factor | 03:01 |
| Protection and UPS equipment | |
| Surge Protection | Yes |
| Overload protection | Yes |
| UPS Login | Circuit breaker |
| Short circuit | Immediate load shedding or tripping of upstream circuit breaker |
| Protect the phone, fax, modem, LAN | 1 * RJ-11/45 |
| Ports and interfaces | |
| Dry contacts | No |
| USB-port | No |
| RS-232 | Determination of low battery, control schedule power on / off the UPS, monitoring of input and output voltages |
| Port emergency shutdown EPO | No |
| SNMP | Built-in expansion slot for SNMP adapter |
| Connections of the generator input | No |
| Parallel UPS connection | No |
| Battery | |
| A type | Lead-acid, sealed, maintenance-free |
| Voltage and battery capacity | 12V / 7AH x 3 |
| Typical recharge time | 8 hours (up to 90% of full battery capacity) |
| Charging Current (Max) | 2A |
| Estimated battery backup time (at 50% load) | ~4,0 min. |
| Estimated battery backup time (at 100% load) | ~13,00 min. |
| Hot-swappable batteries | No |
| Connecting additional battery cabinets | No |
| Cold start | Yes |
| Battery protection | Automatic diagnostics, protection against overcharge and short-circuit |
| Physical parameters | |
| Output connectors | 2 x Euro sockets with redundant power and filtration |
| Dimensions (W * D * B) mm | 350*144*229 mm |
| Weight, kg | 11,5 kg |
| Indication | LCD-display (input and output voltage, current, frequency, battery charge level, load level |
| Sound alarm | Beep in battery mode, when the battery is low, overload and fault charger |
| Case features | |
| Material | Metal (0.5 mm) |
| Environmental Parameters | |
| Acoustic noise | <40 dB (at 1 meter from surface) |
| Working conditions | Humidity 0 ~ 95% non-condensing, temperature 0 ~ 40? C |
| Guarantee | |
| Standard warranty | 1 year |